Victron BMV-712 Smart — 4.3.1. Settings via the head unit

Manual - BMV-712 Smart Note that the battery monitor is unable to detect a 32V nominal battery voltage. If the battery monitor is used with a 32V battery bank, the charged voltage must be set manually using the Charged voltage [29] setting. 4.3. How to change settings Use the display buttons to enter and navigate through the settings menu. Each setting has a number and a name. For example: "01 - Battery capacity". The full list of all battery settings and their corresponding number can be found in the All features and settings [28] chapter. 4.3.1. Settings via the head unit It is also possible (and easier) to make the battery monitor settings via the VictronConnect app.

See the The VictronConnect app [14] chapter on how to do this. Display Select button Setup button + (up) and - (down) buttons BMV head unit display and buttons. To access the settings menu and change settings: Page 13 Configuration Measured voltage Assumed nominal voltage > 36V 48V 1 Start in the main menu. 2 Press SETUP for two seconds to enter the settings menu. 3 The first setting item 01-Battery capacity will be shown. 4 Use the + and – buttons to go to the desired setting item. 5 Press SELECT to access the setting item. 6 Use SELECT and the + and – buttons to customize the setting.