Victron BMV-712 Smart — 4.5.2. Set charged voltage value

Manual - BMV-712 Smart 4.4. Update firmware On a new install, it is recommended to update the firmware of the battery monitor. If there is a newer firmware version available, the VictronConnect app will notify you of this as soon as a connection with the battery monitor is made. Note that the firmware can only be updated via the VictronConnect app. The app needs to be up to date to be able to access the latest firmware. To check if the firmware is up to date or to manually update firmware, connect to the battery monitor using the VictronConnect app and follow the below steps:

Navigate to the product settings by clicking the "cog" symbol in the top right-hand corner of the product status screen. Click on the "3 dots" symbol in the top right-hand corner of the settings screen. Select "Product info" from the pop-up menu. The firmware version will be displayed. It is mentioned if this is the latest firmware version (or not). If a newer firmware version is available, an "UPDATE" button will be displayed. To update the firmware, press the "UPDATE" button. The default settings of the battery monitor are tailored for lead acid batteries, like AGM, GEL, OPzV or OPzS batteries. 4.5. Make essential settings Most settings can stay at their factory default.

But there are a few settings that need to be changed. These are: Battery capacity. Charged voltage. The functionality of the auxiliary input (if used). State of charge or start synchronised. If lithium batteries (or batteries with a different chemistry) are used, some additional settings will have to be changed. First, make the essential settings as described in this paragraph and then refer to the next paragraph for the special lithium settings. For more information about these and any of the other settings, see chapter All features and settings [28] . 4.5.1. Set the battery capacity value In the VictronConnect app, see: Settings > Battery . Via the head unit, see:

Setup menu > Setting 01 - Battery capacity . The battery monitor is by default set to 200Ah. Change this value to match your battery capacity. For lead-acid batteries, we recommend entering the 20-hour (C20) rate. 4.5.2. Set charged voltage value In the VictronConnect app, see: Settings > Battery > Charged voltage . Although the battery monitor automatically detects the voltage, it is good practice to check if this setting is correctly set. Via the head unit, see: Setup menu > Setting 02 - Charged voltage . Page 15 Configuration Nominal battery voltage Recommended charged voltage setting Lithium Lead-acid 12V 13.9 V 14.0 V 24V 27.8 V 28.0 V 36V 41.7 V 42.0 V