Manual - BMV-712 Smart The VictronConnect app battery monitor history screen. 5.5.2. Accessing historical data via the head unit To view the battery monitor history menu press SELECT when in normal mode: Press + or – to browse the various parameters. Press + or – to browse the various values. Press SELECT again to stop scrolling and show the value. Press SELECT again to leave the historical menu and to go back to the normal operation mode. The below table gives an overview of the history parameters and how they are displayed in the menu. For the meaning of each parameter see the next chapter.
Page 21 Operation # Display Discription A Deepest discharge B Last discharge C Average discharge D Cycles E Discharges F Cumulative Ah G Lowest voltage H Highest voltage I Days since last full charge J Synchronisations L Low voltage alarms M High voltage alarms