Manual - BMV-712 Smart The alarm will activate when the value reaches a set threshold and will deactivate when the value clears this threshold. The thresholds are configurable. For more information, see the Alarm settings [34] chapter. The alarm will be displayed on the head unit, a buzzer will sound, the display backlight will flash, and the alarm icon will be visible on the display. An alarm is acknowledged when a button is pressed. However, the alarm icon is displayed as long as the alarm condition remains. The programmable relay can be triggered depending on the configuration of the alarm settings. The alarm is also a software alarm.
When connecting with the VictronConnect app, while an alarm is active, the alarm will show in the app. Alternatively, when the battery monitor is connected to a GX device, the alarm will show on the GX device display or the VRM portal. In the case of the VictronConnect app, an alarm is acknowledged when a button is pressed. And in the case of a GX device, an alarm is acknowledged when viewed in notifications. The alarm icon is displayed as long as the alarm condition remains. Left: alarm displayed on the VictronConnect app. Right: alarm displayed on a GX device. 5.7.
Synchronising the battery monitor For a reliable readout, the state of charge, as displayed by the battery monitor, must self-synchronise regularly with the true state of charge of the battery. This is to prevent drift of the “State of charge” value over time. A synchronisation will reset the state of charge of the battery to 100%. 5.7.1. Automatic synchronisation Synchronisation is an automatic process and will occur when the battery has been fully charged. The battery monitor will look at a few parameters to ascertain that the battery has been fully charged.
It will consider the battery to be fully charged when the voltage has reached a certain value and the current has dropped below a certain value for a certain amount of time. These parameters are called: Charged voltage - the voltage level above which the battery is considered to be fully charged. Tail current - a percentage of the battery capacity. Charged detection time - the time in minutes. As soon as these 3 parameters have been met, the battery monitor will set the state of charge value to 100%, thus synchronising the state of charge. Example: In the case of a 12V battery, the battery monitor will reset the battery’s state of charge to 100% when all these parameters have been met:
The voltage exceeds 14.0V, 3 minutes have passed while both the voltage and current conditions are met. the charge current is less than 4.0% of the total battery capacity (e.g. 8A for a 200Ah battery) and, The three parameters work together. The charged voltage must be set just below the voltage at which the charger completes the charge cycle, usually the absorption voltage. The tail current must be set higher than the current at which the charger stops or reduces charging. The charged detection time makes sure that a short voltage peak does not cause a synchronisation. When the charged voltage is set too low, the battery voltage can exceed it while the battery is not fully charged.
A typical example is a solar system at the end of the day: the battery is still far from full, but the battery voltage is above the charged voltage and the charge current slowly drops as the sun sets. The tail current and charged detection time conditions are then also met, and the battery monitor incorrectly sets the state of charge to 100%. When the charged voltage is set too high, the battery voltage can never reach it. Automatic synchronisation will not take place and the state of charge will start to drift. If the battery monitor does not perform a regular synchronisation, the state of charge value will start to drift over time.
This is due to the small inaccuracies of the battery monitor and because of the estimation of the Peukert exponent [44] . Once a battery Page 23 Operation