Victron BMV-712 Smart — 10.3.3. There is a current reading while no current flows

Manual - BMV-712 Smart solution in such a case is to add a VE.Direct Bluetooth Dongle (ASS030536011) to the system, and switch off Bluetooth in the BMV-712 Smart. Be aware that the VE.Direct Bluetooth Dongle will not support stored trends, Bluetooth GATT service and the Keep SOC option. Are you using the Windows version of the VictronConnect app? This version is unable to connect via Bluetooth. Use Android, iOS or macOS instead (or use the USB - VE.Direct interface). For connection issues, see the troubleshooting section of the VictronConnect manual: https://www.victronenergy.com/live/ victronconnect:start . 10.2.2.

PIN code lost Note that the PIN code is only applicable when connecting to the battery monitor via Bluetooth. If you have lost the PIN code you will need to reset the PIN code to its default PIN code, see the Reset PIN code [42] chapter. More information and specific instructions can be found in the VictronConnect manual: https://www.victronenergy.com/live/ victronconnect:start . 10.3. Incorrect readings 10.3.1. Charge and discharge current are inverted The charge current should be shown as a positive value. For example: 1.45A. The discharge current should be shown as a negative value. For example: -1.45A.

If the charge and discharge currents are reversed, the negative power cables on the battery monitor must be swapped. 10.3.2. Incomplete current reading The negatives of all the loads and the charge sources in the system must be connected to the system minus side of the shunt. If the negative of a load or a charge source is connected directly to the negative battery terminal or the “battery minus” side on the shunt, their current will not flow through the battery monitor and will be excluded from the overall current reading and the state of charge reading. The battery monitor will display a higher state of charge than the actual state of charge of the battery.

If there is a current reading while no current is flowing through the battery monitor, perform a zero current calibration [31] while all loads are turned off or set the current threshold [30] . 10.3.3. There is a current reading while no current flows Page 51 Troubleshooting