HP — ASPSGFinal

If the logic PCA or power supply is replaced, hardware tests must be performed. Note Note Note Note 5-96 hp restricted service & repair message value description power-on and printer response issues Cause 1: Access doors or vents open Check the Access Doors: Make sure the Top Cover and Carriage Access Cover are firmly closed. If the LCD panel displays the message CLOSE ALL COVERS, open and close all access doors. Check the vents: If the printer's vents are covered, and the printer overheats, it automatically turns off. Make sure the vents are not covered and the printer is in a cool, dry location. Cause 2:

Power cord incompatibilities Make sure the printer is connected to the power cord, that the power cord is plugged in, and that the power cord can handle 230V. To test the power cord: Power off the printer, unplug the power cord and replace it with a new power cord, then power on the printer. If the printer now works, then the power cord was faulty. Cause 3: Verify voltage of Power Supply module Disconnect the PS harness from the PS module. Use a multimeter to check the output voltages of the Power Supply Assembly. They should measure same as what’s printed on PS module label. Reconnect the PS harness when you are finished. Turn the printer off and then on again. Cause 5:

Faulty harness Check that all connections to the harnesses are solid and that all connectors are attached firmly to the wires. Ensure that none of the wire insulation is frayed or missing. Check PS voltages at the destination ends of the harnesses.