Delta — Group 0 User Parameters

Chapter 4 Parameters | 4.1 Summary of Parameter Settings  : The parameter can be set during operation. Group 0 User Parameters 4-2 Revision 2016/03, 6ELE, V1.14 Parameter Function Setting Factory Setting Customer 00.00 Identity Code of the AC motor drive Read-only ## 00.01 Rated Current Display of the AC motor drive Read-only #.# 00.02 Parameter Reset 0: Parameter can be read/written 1: All parameters are read only 8: Keypad lock 9: All parameters are reset to factory settings (50Hz, 230V/400V or 220V/380V depends on Pr.00.12) 10: All parameters are reset to factory settings (60Hz, 220V/440V) 0 00.03 Start-up Display Selection 0: Display the frequency command value (Fxxx) 1:

Display the actual output frequency (Hxxx) 2: Display the content of user-defined unit (Uxxx) 3: Multifunction display, see Pr.00.04 4: FWD/REV command 0 00.04 Content of Multi-function Display 0: Display the content of user-defined unit (Uxxx) 1: Display the counter value (c) 2: Display the status of multi-function input terminals (d) 3: Display DC-BUS voltage (u) 4: Display output voltage (E) 5: Display PID analog feedback signal value (b) (%) 6: Output power factor angle (n) 0 7: Display output power (P) 8: Display PID setting and feedback signal 9: Display AVI (I) (V) 10: Display ACI (i) (mA) 11: Display the temperature of IGBT (h) (°C) 00.05 User-Defined Coefficient K 0.

1 to 160.0 1.0 00.06 Software Version Read-only #.## 00.07 Reserved 00.08 Password Input 0 to 9999 0 00.09 Password Set 0 to 9999 0 00.10 Control Mode 0: V/F control 1: Vector control 0 00.11 Reserved