Downloaded from https://www.everyspec.com MIL-STD-100E NOTICE 2 c. Blank spaces are not permitted. d. Symbols such as: parentheses (), asterisks*, degree °, plus +, shall not be used, except when referencing the Government or non-Government standardization document whose identification contains such a symbol. e. The CAGE Code. drawing format size letter, and drawing revision letter (see 602.3) are not considered part of the drawing number. f. Drawing numbering systems shall preclude duplication of assigned numbers. Numbering systems may be based on either non-significant numbers or significant numbers. 406.6 PIN length and applicat PIN’s shall not exceed 15 characters.
This number shall be or shall include the drawing number on which the item is described. Where more than one item is described on a drawing. unique identification shall be provided by the addition of I a suffix identifier, with the following limitations: (For bulk materials see 406.15.4). I a. The total length of the PIN including the suffix identifier shall not exceed 15 characters. I b. The suffix identifier shall have the same characteristics as drawing numbers and may be composed of numbers, letters or any combination thereof. c. Suffix identifiers may be used even if only one item is described on a drawing. d. PIN’s shall not include the drawing revision (see 400.5.e).
400-5 Supersedes page 400-5 of 30 September 1991