Downloaded from https://www.everyspec.com MIL-STD-1311D PULSE EMISSION METHOD 3251A (Hydrogen thyratron) 1. Pulse emission (method A). This test is performed in circuit on figure 3251-1. The emission quality is determined by measuring the grid-cathode voltage during a pulse of current discharged from the pulse forming network. Test conditions shall be as specified on the TSS. 1.1 With the anode floating, a positive pulse shall be applied to the grid of the TUT or the pulse shall be applied to the anode with a 1-ohm resistance between grid and anode.
Voltage (egk) shall be measured as shown on figure 3251-2 between the grid and cathode (anode and cathode in case of the alternate connection) at a point in time not later than the value specified on the TSS after beginning of current pulse. The voltage shall be within the limit(s) for egk specified on the TSS whether the anode or grid voltage is measured and the voltage shall not rise during the conduction time following the point of measurement. 2. Pulse emission (method B). The tube shall be tested for pulse emission in the circuit shown on figure 3251-3.
The emission quality is determined by measuring the grid cathode voltage during a pulse of current discharged from an appropriate pulse generator. Test conditions shall be as specified on the TSS. 2.1 If positive "keep-alive" current is specified on the TSS, it shall be drawn to the grid, with the isolating diode connected to the grid as shown on figure 3251-3. In tubes equipped with an additional or "keep-alive" electrode, the isolating diode shall be connected directly to that electrode. 2.2 A positive pulse shall be applied to the grid of the TUT.
Voltage (egk) shall be measured as shown on figure 3251-2 between the grid and cathode at a point in time not later than the value specified on the TSS after the beginning of the current pulse. The voltage shall be within the limit(s) specified on the TSS and the voltage shall not rise during the conduction time following the point of measurement. NOTE: The TSS shall specify either method A or B. NOTE: Include RV as part of R . FIGURE 3251-1. Pulse emission test circuit. METHOD 3251A 3251-1 25 March 1970