Downloaded from https://www.everyspec.com MIL-STD-1311D MEAN TEMPERATURE COEFFICIENT OF FREQUENCY 1. Purpose. To determine the mean value of the temperature coefficient of frequency over a stated range. 2. Equipment. A test chamber capable of maintaining its environmental temperature (and its cooling fluid temperature, if required) at either of the two stated values. It shall be capable of tube operation. If actual tube temperature is to be varied, alternate methods may be used, such as changes in either the flow rate or temperature of the cooling air or fluid. These methods shall be capable of maintaining the temperature at the designated values. 3. Procedure.

Temperature specified will be ambient temperatures unless (a) spot(s) on the tube surface is (are) designated as reference(s) for temperature measurements. 3.1 The test shall be started with the tube stabilized at ambient temperature and the frequency and operating conditions recorded. The temperature shall then be raised, (normally 30 ° C) at any desired rate to the stated value. After stability is achieved at the applicable operating conditions, the frequency is again recorded. 3.2 The temperature and operating conditions are returned at any desired rate to the first values and frequency again recorded after stability is reached. 4. Definition.

The greater difference between the frequency measured at the upper temperature and the lower temperature divided by the corresponding temperature change is the mean temperature coefficient of frequency. At his option, the manufacturer may average the values obtained from three thermal cycles. METHOD 4004 METHOD 4004 4004-1 19 April 1968