Downloaded from https://www.everyspec.com MIL-STD-1311D 3. Method B (broadband noise source method). 3.1 Test circuit. FIGURE 4260-2 Broadband noise source method. 3.2 Procedure. Tube is operating with all normally specified voltages applied. With the noise source turned off, record the power output - N 1 . With the noise source turned on, record the power output - N 2 . 1 log 10 ) ( 2 N N F NF S dB = )1 ( 1 Where: F S is the ratio of (available power per cycle from noise source) to K T . 3.3 Precautions. 3.3.1 The VSWR looking back into the noise source should be 1.5 maximum.
3.3.2 If it is necessary to change the power level from the noise source, a directional coupler or precision attenuator can be used between noise source and TUT. This will change F S by the coupler or attenuator ratio. 3.3.3 Insure that spurious oscillations are not included in the measurement. 4. Automatic noise figure measurements. It is possible to make method B automatic by pulsing the noise source on and off at an audio rate and reading the noise figure directly on commercially available equipment. METHOD 4260 4260-2 19 April 1968