Downloaded from https://www.everyspec.com MIL-STD-1311D AMPLIFIER POWER BANDWIDTH 1. Purpose. To determine the frequency range between points of specified output power level of an amplifier as the frequency of the driving source is varied. The level may be specified absolutely or relative to the maximum power. 2. Definition. Power bandwidth is defined as the total frequency range over which the output power of a microwave tube exceeds a specified value of output power. Two varieties of bandwidth measurements can be defined as follows: a. Dynamic power bandwidth is measured with a swept-frequency drive source of constant output power level. b.
Static power bandwidth is measured point-by-point at a series of spot frequencies of a constant drive power level. c. Amplifier power bandwidth is frequently specified between the half-power (-3 dB) points, but measurements between other output levels are valid for other applications. The TSS shall show the power level at the band limits when a level other than -3 dB is required. 3. Equipment. Appropriate output power and frequency measuring equipment shall be used for the power levels and frequencies of interest. Output power shall be measured as in method 4250. 4. Procedure. a.
The tube shall be operated under the specified conditions, adjusted as for the power output test and the frequency of the driving power varied through the required excursion by a dynamic (swept) or a static (point by point) technique, as specified, and the output power measured or displayed. When necessary, the sweep rate and other conditions will be specified. b. The driving power frequency shall be varied to change the output of the TUT between the specified output power values and the frequencies at these values shall be measured. Requirements or limits on loading, discontinuities, and hysteresis shall be as specified. 5. Precautions. a.
When the swept technique is used, care shall be taken to insure that the sweep rate is low enough to avoid high frequency instrumentation problems and high enough to avoid any thermal tuning effects. b. In multiple resonator and high-beam current tube types, thermal detuning and beam loading can cause wide differences in the results obtained by the dynamic and the static methods. METHOD 4271A METHOD 4271A 4271-1 25 March 1970