Downloaded from https://www.everyspec.com MIL-STD-1311D 3. Procedure. 3.1 Power meter measuring circuits 3.1.1 With the tube in the test circuit, the ignitor current or voltage and the rf power in the main line shall be adjusted to the specified values. The average leakage power shall be measured at each of two pulse durations, tp1 and tp2. These are the durations of the power generator pulses measured as in method 4304, while tp3 and tp4 are the corresponding leakage pulse durations measured at the base line of the leakage pulses passing through the TUT. 3.1.2 The peak flat-leakage power (pf), in milliwatts, shall be computed by using the following formula:
tp tp prr x P P pf = ) 4 3 ( 10 ) 2 1 ( 3 Where: tp3 = Leakage pulse width of longer pulse, in seconds, measured at the baseline. tp4 = Leakage pulse width or shorter pulse, in seconds, measured at the baseline. P1 = Average leakage power at tp1, in watts. P2 = Average leakage power at tp2, in watts. 3.1.3 The spike-leakage energy, in ergs, shall be computed by using the following formula: tp tp tp P P P prr Ws = 4 3 3 ) 2 1 ( 1 10 7 Where the terms are defined in 3.1.2.
3.1.4 If it is possible to adjust the pulse width, tp2, to a very small value so that the leakage pulse consists mainly of the spike and essentially no flat, the spike-leakage energy may be computed using the following formula: 2 10 7 P prr Ws = Where: P2 = Average leakage power, in watts, at the shorter pulse width. 3.2 Oscilloscope measuring circuits. 3.2.1 To calibrate the oscilloscope, connect the two circuits, figures 4452-2 and 4452-3 together, or if they are branch circuits of a complete leakage power test setup, use the following procedure. With the power from the signal generator, calibrate the oscilloscope to some selected value of peak power using attenuator No.
1 with no tube in the circuit. Knowing the duty cycle at which the signal generator is operating, the peak power indicated on the oscilloscope can be calculated by dividing the average power measured with the power meter by the duty cycle. 3.2.2 With the signal generator turned off or disconnected, insert the TUT into the circuit, adjust the ignitor to its specified current or voltage, and set the rf power conditions in the main line to those specified on the TSS. With no change in the oscilloscope controls, attenuator No. 2 is adjusted to bring the peak of the spike or the flat to the calibrated reference level set on the oscilloscope.
The peak power value of the spike, ps, or the flat, pf, obtained by multiplying the reference level peak power by the power ratio obtained from the attenuator. The width of the spike, ts, is measured in nanoseconds at the 3 dB level on the spike portion of leakage pulse and is used in calculating the spike-leakage energy. METHOD 4452A 4452-5 18 August 1970