Downloaded from https://www.everyspec.com MIL-STD-1311D HIGH-LEVEL VSWR METHOD 4474 (Gas-switching tubes) 1. Purpose. To measure the magnitude of the discontinuity in the main transmission line, when the switching tube is ionized. 2. Equipment. The tube shall be mounted as a series tee in the main line using the specified mount. Figure 4474-1 shows the basic circuit for single tubes, and figure 4474-2 shows the circuit for dual tubes. FIGURE 4474-1. Equipment layout for single tube high-level VSWR measurement. FIGURE 4474-2. Equipment layout for dual tube high-level VSWR measurement. 3. Procedure.

With the power in the line set to the specified conditions, the VSWR in the line shall be measured. 4. Precautions. The high-power termination used shall have a VSWR which is well below the limit specified for the TUT. The 3 dB hybrid coupler used shall have a VSWR of less than 1.10, shall split the power evenly to within 0.25 dB, and shall have a minimum isolation of 25 dB. METHOD 4474 4474-1 19 April 1968