Downloaded from https://www.everyspec.com MIL-STD-1311D DEFLECTION FACTOR METHOD 5248 (Cathode-ray tubes) 1. Deflection factor. With the test conditions specified, the deflection factor (the ratio of the deflecting voltage to the corresponding deflection in inches as determined on each axis by deflecting the beam from a position 75 percent useful scan radius, left or up from center, to a position 75 percent useful scan radius, right or down from center) shall be within the limit(s) specified. 2. Deflection-factor uniformity. The deflection-factor uniformity on each deflection axis shall be determined.

For any axis, the deflection factors corresponding to 25 and 75 percent of the minimum useful scan radius shall be measured from center of useful scan along the tube-face contour. Measurements on each axis shall be made on both sides from the center. The factor at 25- percent deflection shall not differ from the factor at 75-percent deflection, on the same side of the center of the useful scan, by more than 5 percent. METHOD 5248 5248-1 19 April 1968