Downloaded from https://www.everyspec.com MIL-STD-1311D SPOT POSITION METHOD 5404A (Cathode-ray charge storage tubes) 1. Purpose. The purpose of this method is the determination of the undeflected spot position of the TUT. 2. Equipment. Pulse generators, amplifiers, deflection systems, monitoring equipment, as required, shall be adequate to operate and observe the TUT. 3. Procedure. The TSS shall specify which of the following shall be used. 3.1 Method A for magnetic-deflection tubes. a. The TUT shall be operated at the test conditions specified in the TSS. b.
Special attention shall be given to the control-grid to cathode voltage in order to assure a value which will avoid damage to the storage surface or screen, under the undeflected spot conditions of this test. It is permissible to employ a variable amplitude and variable duty cycle intensification pulse. c. If the TUT is a magnetic focus type, it shall be operated with the focus coil at the focus coil position as specified in the TSS and with no external alignment fields present. The focus current shall be a minimum consistent with a viewable spot. It shall then be demonstrated that a variation in focusing field does not cause deflection. d.
If the TUT has electrostatic focus, the spot shall be adjusted for focus. e. With the tube operating as above (no deflection), the distance between the center of the undeflected spot and the center of the storage surface or screen shall be recorded and it shall be within the limits specified in the TSS. With off-centered guns, the undeflected spot position shall fall within a circle whose radius and center position are specified in the TSS. 3.2 Method B for electrostatic-deflection tubes. a. The TUT shall be operated at the test conditions specified in the TSS. b.
Special attention shall be given to the control-grid to cathode voltage in order to assure a value which will avoid damage to the storage surface or screen, under the undeflected spot conditions of this test. It is permissible to employ a variable amplitude and variable duty cycle intensification pulse. c. The tube shall be adjusted for focus with each of the deflecting electrodes connected to the average dc potential specified in the TSS and with no external alignment fields present. d.
The undeflected spot position shall be recorded and shall be within the rectangular limits specified in the TSS, the center of which coincides with the specified location on the storage surface or screen and one side to be parallel to a trace produced by one set of deflecting electrodes. 4. Precautions. a. For electrical output storage tubes, the linearity of the reading sweeps on the tube and on the monitor shall be adequate for determining spot location. b. Utmost care should be taken in preventing surface damage due to lack of deflection. c. Shielding may have to be provided if the TUT is influenced by external magnetic and electrical fields. METHOD 5404A 5404-1 12 December 1972