Downloaded from https://www.everyspec.com MIL-STD-1311D METHOD 1016 MOISTURE RESISTANCE 1. Procedure. The tubes shall be tested in accordance with method 106 of MIL-STD-202, except that step 7 shall be omitted. After the holding period of 24 hours at room ambient conditions, electrical measurements as specified on the TSS shall be made. METHOD 1016 1016-1 19 April 1968