Downloaded from https://www.everyspec.com MIL-STD-1311D The modulation transfer function and phase shift values are calculated using the following equations: X Y MTF πυ πυ = 2 / 1 2 2 2 sin 2 cos + X Y i p i i P Y Y i p i i i i i i 2 sin ) ( tan X Y PHI πυ i p i i p X Y = πυ i p i i 2 cos Where: P = Spatial frequency in terms of cycles/SSRD for which the modulation is determined. Y i = The value of the line spread function at point X i . ν p = The frequency equivalent of p (cycles/ t). t = Time increment between values of X. X i = The assigned abscissa integer values of the line spread function. k.
A typical computer program using the equations in 3j (in the super basic language) for obtaining MTF from tabulated line spread function data, as in table 5422-I, is shown in table 5422-II. This program will interrogate the user for the data required and ask for the maximum spatial frequency to which MTF calculations are required. Once these data are entered, the program will calculate and print out the cycles/SSRD in increments of 25 cycles with their respective MTF values. In addition, it calculates and prints the tangent of the phase shift between the input and output signals. l.
The MTF data obtained from the Fourier transform may be presented in tabular or graphical form, the only requirement being that there be sufficient resolution in the presented data to permit visual review and interpretation, particularly in the response regions of 0.70, 0.50, 0.10, and 0.04. If graphical presentation is employed, this may be done using log-linear log-log, or linear scaled paper. The abscissa shall be in terms of "Spatial Frequency" in units of "cycles/SSRD", and the ordinate shall be in terms of "Modulation" in units of "relative response". m.
A typical presentation of the modulation transfer function as in 3l above, may be in the form of computer print out as in table 5422-II or as shown on figure 5422-3. METHOD 5422 5422-4 12 December 1972