Downloaded from https://www.everyspec.com MIL-STD-1311D 4. Precautions. a. The purpose of this test method is to obtain the MTF of the TUT. Thus, read and oscilloscope amplifiers shall be provided that have bandwidths which, when referred to the scanned portion of the storage surface, provide responses at spatial frequencies well beyond the limiting resolution. b. For this test to provide meaningful results, the tube and its support equipment shall be operated in their linear ranges. The linear range is that range of operation over which the output signal is essentially proportional to the input signal. c.
For a more comprehensive measurement of MTF, data can be taken at a number of locations on the storage surface, in different scan directions, and at different scan rates. d. When generating the data table called for in 3g, it is important that the end points (zero values) of the pulse be located at zero amplitude and not on a disturbance or perturbation of the baseline. Several measurements 3e(1) can be made at adjacent locations in the storage tube to help determine where the true baseline signal is located. Incorrect establishment of the baseline will cause the resultant MTF to be in error. 5. TSS requirements. The TSS shall specify the following. 5.1 Equipment. a.
Writing deflection system sweep speed(s) (see 2a). b. Reading deflection system repetition rate (see 2b). c. When used, external focus and deflection component locations (see 2c). 5.2 Procedure. a. Operating conditions for the test (see 3a). b. The area in which the measurement(s) is to be made (see 3a). c. Single-cycle writing sweep rate (see 3d). METHOD 5422 5422-11 12 December 1972