Department of Defense MIL-STD-1311D — MIL-STD-1311D Test Methods for Electron Tubes — DoD Standard Manual PDF

Downloaded from https://www.everyspec.com MIL-STD-1311D DISPLAY PERSISTENCE, VISUAL OUTPUT METHOD 5425 (Cathode-ray charge storage tubes) 1. Purpose. The purpose of this test is to determine the time required for a written display to decay from one luminance level to another under controlled erased conditions. 2. Definition. Saturation level is that level of luminance beyond which no further increase in luminance is produced by additional writing. The tube can be written to saturation level by writing up the entire viewing area with the erase pulse amplitude set at zero and then cutting off the write beam. 3. Equipment. a.

A photometer shall be used to measure the luminance of the TUT over a circular area 10 ± 5 mm (approximately .4 ± .2 inch) in diameter. b. A stop watch or other elapsed time indicator shall be used. c. A deflection system shall produce a merged raster on the TUT with linear sawtooth deflections in orthogonal directions. 4. Procedure. a. Operating conditions shall be as specified in the TSS. b. Without simultaneously erasing, write all of the area specified in the TSS to the saturation level. c. Stop writing. Apply an erase pulse train of the specified duty cycle and establish the pulse train amplitude required to reach the cutoff point in the area of interest.

This is accomplished by alternately writing to the saturation level and erasing, while adjusting the amplitude of the erase pulse train. The cutoff point is to be determined in the absence of background luminance caused by the erase pulse train. d. Without simultaneously erasing, write all of the area specified in the TSS to the saturation level or the luminance level specified. e. Stop writing. Apply an erase pulse train whose amplitude equals the value determined in 4c. f. Measure and record the time from the application of the erase pulse train until the written display decays to the level specified. This level shall not include the background luminance caused by the erase pulse train.

This is display persistence. 5. Precautions. To assure that stray light sources do not significantly affect luminance measurements, the light level recorded by the photometer in the measurement position shall be such that, with the TUT off, the photometer reading does not exceed 3 percent of the TUT luminance value to be measured. 6. TSS requirements. a. In addition to the operating conditions for the TUT, the TSS shall specify the following: (1) The area of the display within which display persistence is to be determined (see 4b). (2) Erase pulse train duty cycle (see 4c). (3) The luminance level to which the display is permitted to decay (see 4f). b.

If values other than those specified in this test method are required, the TSS shall specify: The luminance level to which the display is written (see 4d). METHOD 5425 5425-1 12 December 1972