Department of Defense MIL-STD-1311D — MIL-STD-1311D Test Methods for Electron Tubes — DoD Standard Manual PDF

Downloaded from https://www.everyspec.com MIL-STD-1311D 2.3 Non-Government publications. The following documents form a part of this standard to the extent specified herein. Unless otherwise indicated, the issue in effect on date of invitation for bids or request for proposal applies. NATIONAL CONFERENCE OF STANDARDS LABORATORIES (NCSL) NCSL-Z540.3 - Laboratories, Calibration, and Measuring and Test Equipment (DoD adopted). (Copies are available online at http://www.ncsli.org or from National Conference of Standards Laboratories [NCSL], 2995 Wilderness Place Suite 107, Boulder, Colorado 80301-5405.) ELECTRONIC COMPONENTS ASSOCIATION (ECA) EIA-256-A - Deflecting Yokes for Cathode Ray Tubes.

EIA-501-A - Recommended Practice for the Measurement of X-Radiation from Raster-Scanned Direct- View Data Display Cathode-Ray Tubes. EIA-502-A - Recommended Practice for Measurement of X-Radiation from Non-Raster-Scanned Direct- View Cathode Ray Tubes. EIA-503-A - Recommended Practice for Measurement of X-Radiation from Direct-View Television Picture Tubes. EIA-191-D - Measurement of Direct Interelectrode Capacitances of Electron Tubes. EIA-209-A - Electron Tubes Supplement 1- 1965; Supplement 2 - 1968 R (1976). (Copies of these documents are available online at http://ec-central.org or from Electronic Components Association, 2500 Wilson Boulevard, Suite No.

310, Arlington, VA 22201.) 2.4 Order of precedence. Unless otherwise noted herein or in the contract, in the event of a conflict between the text of this document and the references cited herein (except for related specification sheets), the text of this document takes precedence. Nothing in this document, however, supersedes applicable laws and regulations unless a specific exemption has been obtained. 3. DEFINITIONS For the purpose of this standard, the abbreviations, symbols, and definitions are specified in appendices A and B of MIL-PRF-1. 4. GENERAL REQUIREMENTS 4.1 Numbering system. The test methods are designated by numbers assigned in accordance with the following system.

4.1.1 Category of tests. Each test method is designated by a four-digit number, with significance, assigned in accordance with the following criteria: a. Category of tubes Numerical series (first digit) General (tests applicable to more than one tube category) .................................. 1000 to 1999 Receiving, transmitting, and power ...................................................................... 2000 to 2999 Cold cathode, corona and glow discharge voltage regulators, graphic indicator, ignitron pulse modulators, and thyratrons ...............................

3000 to 3999 Crossed field, gas switching, klystrons, magnetrons, M-backward wave, O-type backward wave, and traveling-wave tubes ................................... 4000 to 4999 Cathode ray, cathode-ray charge storage, phototubes, image orthicons, and vidicons ...................................................................................................... 5000 to 5999 Radiation counter ................................................................................................ 6000 to 6999 b. Within the above series, numbers will be assigned as follows:

Category of tests Last three digits of series Environmental/Mechanical (physical) ................................................................... 001 to 199 Electrical .............................................................................................................. 200 to 499 Life .................................................................................................................. 500 to 699 4.1.2 Revisions. Revisions to test methods will be indicated by a capital letter following the method number. For example, the first revision of method 1001 will be 1001A. Letters I and O will not be used. 2