Department of Defense MIL-STD-322B — MIL-STD-322B: Explosive Components, Electrically Initiated, Basic Evaluation Tests User Manual PDF (EN)

Downloaded from https://www.everyspec.com MIL-STD-322B 20 March 1984 1. SCOPE 1.1 General. This standard has a two-fold purpose, establishing tests and procedures which electrically initiated explosive components must pass as well as characterizing electroexplosive device (EED) designs. 1.2 Application. This standard applies to electrically initiated explo– sive components prior to completion of developrnent~ 1.3 Computer Program. A Fortran IV computer program, which fits a Weibull response function to data from either a Bruceton or OSTR conducted test, is available”at ARDC, AMCCOM, DRSMC-LCS-E(D), Dover, NJ.

Point and confidence interval estimates of percentage points and reliabilities (or response probabil- ities.)are also provided by the program. 2. REFERENCED DOCUMENTS 2.1 Issues of documents. The following documents of the issue in effect on date of invitation for bids or request for proposal, form a part of this standard to the extent specified her:ein. SPECIFICATIONS MILITARY MIL-I-23659 Initiators, Electric, General Design Specifications for : STANDARDS MILITARY MIL-STD-331 Fuze and Fuze Tests for Components Environmental and Performance PUBLICATIONS Navy - NAVORD Report No. 2101 Statistical Methods Appropriate for Evalu– .-.

ation of Fuze Explosive - Train Safety and Reliability Army - Safety Manual AMC-R-385-1OO (Copies of specifications, standards, drawings, and publications required by contractors in connection with specific procurement functions should be obtained from the procuring activity or as directed by the contracting officer.) 1