Downloaded from https://www.everyspec.com MIL-STD-705C systems shall be made unless permitted by the procur t. ement documen Adjustments to the load, voltage or frequency controls shall be recorded on the data sheet. Unless otherwise specified in the procurement document, stabilization will be considerd to have occurred when four consecutive voltage and current recorded readings of the generator (or exciter) field either remain unchanged or have only minor variations about an equilibrium condition with no evident continued increase or decrease in value after the last adjustment to the load, voltage or frequency has been made. b. Perform one of the following produres.

670.1.3.2.1 Balance scale Procedure. a. Supply fuel from auxiliary container mounted on a platform balance or other scale. After stabilization has occurred, set the balance weights at any convenient value slightly less than the total weight of the fuel and container. Start the stopwatch when the balance weights fall and record the total weight. Reduce the balance weight a convenient amount and record the amount of the weights removed. Stop the stopwatch when the balance weights fall and record the total weight and the elapsed time. Repeat steps a thru d above until the timed portion of the test exceeds the test duration in table I.

From the total elapsed time and total of the weights removed determine the fuel consumption in terns of pounds per hour as follows: b. c. d. e. f. g. Fuel Consumption = Pounds Hours h. Using the value obtained in step f above, compute the rate of fuel consumption per kilowatt hour, as follows: Pounds per kWH = Fuel Consumption in Pounds per Hour kW Load i. Repeat 670.1.3.2 for each load rendition specified in the procurement document. j. Determine the capacity of the generator set fuel tank in pounds of fuel. k. For each specified load, compute the number of continuous hours the generator set will operate on a full tank of fuel. The following formula shall be used.

Operating Hours = Fuel Tank Capacity (Pounds) Fuel Consumption (Founds per Hour) 670.1.3.2.2 Alternate procedure for weighing fuel. a. Supply fuel from the auxiliary fuel container, mounted on a platform balance, or other weighing device. Method 670.1b 2