Department of Defense MIL-STD-705C — MIL-STD-705C Generator Sets Engine-Driven Test Methods Standard PDF

Downloaded from https://www.everyspec.com MIL-STD-705C b. The voltage and frequency shall be recorded continuously throughout the duration of this method. The minimum chart speed shall be 6 inches per hour except as otherwise specified in the individual performance tests. At the time of each instrumentation reading the voltage and frequency recording chart(s) shall be marked with the time of day, elapsed hours of test and corresponding data reading number. Any indications of abnormal or unusual set performance, with explanation, shall be included on the data sheets. c.

Immediately prior to the scheduled maintenance and servicing of any item specified in the procurment document, perform method 608.1, Frequency and Voltage Regulation, Stability and Transient Response Test (Short Term), for rated load only omitting stabilization requirements. All operating time during the performance of this paragraph shall be included as reliability-creditable hours. (NOTE: In the event service is performed more frequently than at 100-hour intervals, the minimum time between the performance of method 608.1 shall be 100 hours.) d.

In addition to the data recorded above, a separate log book identified by set nomenclature and serial number shall be maintained throughout the reliability evaluation. The log book shall contain, as a minimum, the following information: 1. Date, shift hours, elapsed reliability hours and brief statement on the prevailing weather conditions. All adjustments, if rode, as permitted by the procurement document 2. 3. and man-hours expended. Information regarding scheduled and unscheduled maintenance performed. This shall include clock hours, inn-hours, and number of men to perform each service or maintenance operation. Title, method number, and data sheet numbers for all performance checks.

All shutdowns, with explanation. Results of pericdic visual inspection of the set. In a separate section of the log book, all replacement or repair of parts and oil consumption between oil charges shall be tabulated. These entries shall also include elapsed reliability hours, total set hours (set hour meter reading) and date. 4. 5. 6. 7. e. In addition to the data recorded above, failure analysis sheets shall be prepared for each incident and shall be reported on fores similar to that in figure 695.1-I. TABLE I Method 695.1a 3