Downloaded from https://www.everyspec.com MIL-STD-705C METHOD 420.1b SHORT CIRCUIT RATIO TEST 420.1.1 General. The short circuit ratio is used by design engineers in the evaluation and comparison of the regulation and stability of generators. 420.1.2 Apparatus. Instrumentation for measuring terminal voltage, generator speed, exciter field voltage and current (generator field voltage and current, if applicable), and line current shall be as described and illustrated in MIL-HDBK-705. In addition, a prime mover having a steady state speed not greater than ±1 percent of rated speed and a separate, variable dc source for excitation shall be required.
Electrical instrumentation for this test shall have an accuracy of ±0.5 percent of reading or better. 420.1.3 Procedure. a. Perform method 410.1, Open Circuit Saturation Curve Test (measure the generator field current.) b. Perform method 411.1, Synchronous Impedance Curve Test. 420.1.4 Results. a. From the open circuit saturation curve determine the generator field current required to generate rated open circuit armature terminal voltage. In figure 420.1-I, this value is represented by the distance I fgx b.
From the synchronous impedance curve (the short circuit saturation curve), determine the generator field current required to produce rated armature short circuit current for a sustained symmetrical short circuit at the generator terminals. In figure 420.1-I, this value is represent by the distance I fsi . c. Compute the short circuit ratio by dividing the value obtained in step a above, by the value obtained in step b above. This computation is represented by the following formula: SCR = I fgx I f s i where: SCR is the short circuit ratio. d. Compare the calculated short circuit ratio with the procurement document requirements. 420.1.5 Procurement document requirements.
The following items specified in the individual procurement document: must be a. The allowable range of short circuit ratio, if applicable. b. The voltage connection(s) and frequency(ies) at which this method is to be performed. Method 420.1b 1