Downloaded from https://www.everyspec.com MIL-STD-705C 424.1.3.3 Computations. The determination of the quadrature-axis synchronous reactance is made from an interpretation of the oscillogram obtained in 424.1.3.2, step f above when the genera tor was being driven at a reduced speed. Under these conditions, the quadrature-axis synchronous reactance is in effect when the impedance is at a minimum (i.e., when the ratio of rms armature voltage to rms armature current is at a minimum). The direct-axis synchronous reactance is in effect when the ratio of rms armature voltage to rms armature current is at a maximum. a.

From the oscillogram taken in 424.1.3.2, step f, determine the rms values of line-to-line voltage and the rms values of line current at each peak. Tabulate these values against time in cycles, as shown in the sample tabulation (figure 424.1-V). Each value of line-to-line voltage shall be expressed as a decimal fraction of rated line-to-line voltage. Each value of line current also shall be expressed as a decimal fraction of rated line current (see procedure 4, figure 424.1-III). Divide each value of rms voltage (expressed as a decimal), by the corresponding rms current (expressed as a decimal).

These values shall be tabulated and used as a basis for plotting a curve (figures 424.1-V and 424.1-VI). These ratios shall be plotted versus time in cycles (figure 424.1-VI). The approximate per unit direct-axis synchronous reactance is the maximum value of the ratio obtained in step b above. The approximate per unit quadrature-axis synchronous reactance is the minimum value of the ratio obtained in step b above. The ohmic values of direct-axis and quadrature-axis synchronous reactance are the unit values obtained in steps d and e above, multiplied by base ohms. The base ohms are determined by dividing rated phase voltage by rated phase current. b. c. d. e. f. 424.1.4 Results.

Compare the value of quadrature-axis synchronous reactance obtained in 424.1.3 with the procurement document requirements. 424.1.5 Procurement document requirements. The following items must be specified in the individual procurement document: a. The voltage connection(s) and frequency(ies) at which this method shall be performed. b. The maximum, minimum or range of allowable quadrature-axis synchronous reactance, if applicable. Method 424.1b 2