Victron MultiPlus-II 2x120V — 7. Technical specifications

MultiPlus-II 2x120V 7. Technical specifications Page 25 Technical specifications MultiPlus-II 2x120V 12/3000/120-50 12/4k/160-50 24/3000/70-50 PowerControl & PowerAssist Yes (on L1 input) Transfer switch 50A Maximum AC input current 50A (each leg) INVERTER DC Input voltage range 9.5 – 17V 9.5 -17V 19 - 33V Output in inverter mode Output voltage: 120VAC ± 2% Frequency:

60Hz ± 0.1% Continuous output power at 25°C/77°F (3) 3000 VA 3000 VA Continuous output power at 25C/77°F 2400 W 3.4 kW 2400 W Continuous output power at 40C/104°F 2200 W 3.1 kW 2200 W Time limited power 1 (cold start) 4.0kW/1h Continuous output power at 65C/150°F 1700 W 2.4 kW 1700 W Time limited power 2 (cold start) 4.5kW/30min Peak power 5500 W 6 kW/2s 5500 W Maximum efficiency 93% 93% 94% Zero load power 15 W 18 W 11 W Zero load power in AES mode 10 W 11 W 8 W Zero load power in Search mode 4 W 4 W 4 W CHARGER AC Input Split phase: 180-280 VAC 55 – 65 Hz Single phase:

90-140 VAC 55 – 65 Hz Charge voltage 'absorption' 14.4 V 14.4 V 28.8 V Charge voltage 'float' 13.8 V 13.8 V 27.6 V Storage mode 13.2 V 13.2 V 26.4 V Maximum battery charge current (4) 120 A 160 A 70 A Battery temperature sensor Yes GENERAL Auxiliary output (5) 50A (each leg) See note 8 External AC current sensor (optional) 100 A Programmable relay (6) Yes Protection (2) a – g VE.Bus communication port For parallel and three phase operation, remote monitoring and system integration General purpose communication port (7) Yes, 2x Remote on-off Yes Operating temperature range -40 to +65°C (-40 - 150°F) fan assisted cooling Humidity (non-condensing) max 95% ENCLOSURE Material & Colour Steel, blue RAL 5012 Protection category IP22