MultiPlus-II inverter/charger Australia Built-in Battery Monitor The ideal solution when the MultiPlus-II is part of a hybrid system (diesel generator, inverter/chargers, storage battery, and alternative energy). The built-in battery monitor can be set to start and stop the generator: Start at a preset % discharge level, and/or start (with a preset delay) at a preset battery voltage, and/or start (with a preset delay) at a preset load level. Stop at a preset battery voltage, or stop (with a preset delay) after the bulk charge phase has been completed, and/or stop (with a preset delay) at a preset load level.
Programmable analogue/digital input/output ports (Aux in 1 and Aux in 2, see appendix) The MultiPlus-II is equipped with 2 analogue/digital input/output ports. These ports can be used for several purposes. One application is communication with the BMS of a lithium-ion battery. Programmable settings All settings can be changed with a computer and free of-charge software, downloadable from our website www.victronenergy.com . 2.2. Battery charger 2.2.1. Lead-acid batteries Adaptive 4-stage charge algorithm: bulk – absorption – float – storage The microprocessor-driven adaptive battery management system can be adjusted for various types of batteries.
The adaptive function automatically adapts the charging process to battery use. The right amount of charge: variable absorption time In the event of slight battery discharge, absorption is kept short to prevent overcharging and excessive gas formation. After deep discharging, the absorption time is automatically extended in order to fully charge the battery. Preventing damage due to excessive gassing: the BatterySafe mode If, in order to quickly charge a battery, a high charge current in combination with a high absorption voltage has been chosen, damage due to excessive gassing will be prevented by automatically limiting the rate of voltage increase once the gassing voltage has been reached.
Less maintenance and aging when the battery is not in use: the Storage mode The Storage mode kicks in whenever the battery has not been subjected to discharge during 24 hours. In the Storage mode float voltage is reduced to 2.2V/cell (13.2V for 12V battery) to minimise gassing and corrosion of the positive plates. Once a week the voltage is raised back to the absorption level to ‘equalize’ the battery. This feature prevents stratification of the electrolyte and sulphation, a major cause of early battery failure. Battery voltage sense:
the correct charge voltage Voltage loss due to cable resistance can be compensated by using the voltage sense facility to measure voltage directly on the DC bus or on the battery terminals. Battery voltage and temperature compensation The temperature sensor serves to reduce charging voltage when battery temperature rises. This is particularly important for maintenance-free batteries, which could otherwise dry out by overcharging. The temperature sensor is not supplied with 48V models. It can be ordered separately. Order number: ASS000001000 Two DC outputs for charging two batteries The main DC terminal can supply the full output current.
The second output, intended for charging a starter battery, is limited to 4A and has a slightly lower output voltage (12V and 24V models only). Page 4 Description