Nucleo GX Manual 14.2.4. GX device configuration No other settings such as IP addresses or similar are required, since the Axiom MFDs have an integrated DHCP server. 14.2.5. Configuring Multiple Tank Level Measurements (Raymarine) Modern Raymarine Axiom MFDs are capable of displaying up to 16 tank levels and smaller MFDs such as the i70 or i70s can display up to 5 tanks. The following restrictions apply: 1. Currently, the Axiom can only display Fuel (default), Fresh Water, Waste Water aka Grey Water, Live Well, Black Water and Gasoline fluid types. The other fluid types such as LNG, LPG, Hydraulic oil and Diesel are not displayed.
This is a Raymarine limitation, which may change with a future firmware update. However, it is possible to configure a specific tank sender's fluid type in the GX device menu to one of the supported ones, and then rename the tank in the Axiom tank settings (Boat Details > Configure Tanks > Tank Settings) to whatever you like, e.g. LPG, which is then displayed as LPG tank on the dashboard. 2. The i70 and i70s will display up to 5 tanks where the fluid type must be Fuel. All other fluid types are not displayed. 3. For instancing requirements, see the Instancing requirements when using Raymarine section further below. 4.
All tank senders as mentioned in the chapter Connecting Victron products and Connecting supported non-Victron products are supported. Configuration step-by-step Before proceeding with the following steps, you must connect the GX device to the NMEA 2000 network to which the MFD is connected. Use our VE.Can to NMEA 2000 micro-C male cable to connect the GX device to the NMEA 2000 network and ensure NMEA2000-out of the VE.Can port is enabled in the GX device. The procedure below does not replace the Raymarine manual; Be sure to read the Raymarine documentation that accompanies your Raymarine MFD. Visit the Raymarine Manuals and Documents website for the latest version 1.
Connect the tank sensors to your GX device. 2. Make sure the tank sensors are set to a fluid type supported by your MFD. Page 123 Marine MFD integration by App 1. On the Victron GX device, go to Settings → Integrations, and there enable MQTT Access. 2. Next, go to Settings → System Setup → Batteries → Battery Measurements, and there set up what batteries you want to see on the MFD; and by what name. 3. For boats, RVs and other applications with DC loads such as lighting and a Battery Monitor installed, make sure to enable the “Has DC system setting”. For more information about it, see the Menu structure and configurable parameters chapter.