Nucleo GX Manual 2. Actisense NMEA-Reader software + NGT-1 USB: Device and Data instances 3. Maretron software + USB adapter: Unknown (see Maretron documentation) 4. Commandline of a GX device: Device and Data instances. Note that this required advanced Linux skills; and is listed here only for the benefit of experienced software developers Notes on changing Data and Device instances Data instance: Even though we recommend not changing Data instances (see the explanation and WARNING above), it is possible to change them. The GX device has no option to change them - a third-party tool is required. The only tool we are aware of that can perform this function is the Actisense NMEA 2000 Reader.
The Battery instance and the DC instance are the same value within Victron products. Changing one of them, will also change the other one. Since the BMV sends out two voltages, the main voltage and the aux- or starter-voltage, it comes preconfigured with two battery instances: 0 and 1. When you want to change that to 1 and 2, change the 1 into 2 first, and then the 0 into 1, as they cannot be the same. Since Solar Chargers send two sets of voltage and current data (one for the battery charging output and one for the solar input), these are configured by default as Data instance 0 for the battery charging output and Data instance 1 for the solar input.
The device type is set to Battery for the charging output and Solar Cell for the solar input. Since Orion XS DC-DC battery chargers send two sets of voltage and current data (one for the output and one for the input), these are configured by default as Data instance 0 for the output and Data instance 1 for the input. The device type is set to Battery for the output and Converter for the input. AC chargers can send up to three instances of voltage and current data, one for each battery charging output. By default, these are configured as Instance 0 for output 1, Instance 1 for output 2, and Instance 2 for output 3. Changing the fluid level instance using Actisense has a bug.
Probably due Actisense seeing it as 8 bit number; while in the definition it is a 4 bit number. Work around: using the GX, set the fluid type to Fuel (0), then using Actisense change the fluid instance to the desired value, and then using your GX, set the type back to the desired type. Device instance: WARNING: these (Victron-)features depend on the Device instance: 1. For an ESS system with Solar chargers connected to a VE.Can network, those Solar chargers must remain to be configured to their default Device instance (0) for proper operation. This does not apply to VE.Direct-connected Solar chargers made available on the CAN-Bus as a Virtual-device, using the NMEA 2000-out function.
Unless the Device instance of the GX device is re-configured to another Device instance. Which is technically possible but not advised and also never required. But in that situation, the chargers must be configured to the same instance as the GX device. 2. For systems with managed batteries, the same. 3. For both, Solar chargers, as well as AC-connected battery chargers, when connected in a VE.Can network, they will synchronise their operation, charge state and such. All chargers must be configured to the same Device instance for that function to work. In summary, for most systems, we recommend leaving the Device instance to its default, 0. Remote Console on a GX device:
Changing the Device instance: Page 147 Marine MFD integration by NMEA 2000