Victron Nucleo GX — 15.8.5. NMEA 2000 Changing Instances

Nucleo GX Manual Maretron N2KAnalyzer: Maretron uses a term called “Unique Instance” where the N2KAnalyzer software tool automatically determines if a particular device uses Device or Data instances. WARNING: At Victron we do not understand what and how the Maretron software works with regards to this. We advise to use another tool, not Maretron, so that you know what you are doing, ie know what instance you are changing. So far, we have not been able to use Maretron software to change a Data instance. And changing the other instance, the Device instance can also be done straight from the Victron GX device its user interface.

To change a Data instance, for example to fix instance conflicts as reported by the Maretron software, we recommend to use Actisense. Not Maretron. Changing the instances from the GX command line: Instead of using Actisense or Maretron software, it is also possible to change the VE.Can aka N2K Device instance from the GX Device shell. To get root access, follow these instructions: Venus OS: Root Access . Once logged into the shell, follow below instructions. More back ground information of the used commands such as dbus and dbus-spy is found by reading about root access document. WARNING: Better use an Actisense!

The procedure described in the following paragraphs is not normally recommended. Use an Actisense instead, see the Actisense method explained earlier. New method - changing a Device instance: All devices available on the canbus are enumerated under the com.victronenergy.vecan service. And for all devices that support the necessary can-bus commands, the Device instance can be changed. All Victron products support changing their Device instance; and most or all non-Victron products as well. # dbus -y com.victronenergy.vecan.can0 / GetValue value = { 'Devices/00002CC001F4/DeviceInstance': 0, 'Devices/00002CC001F4/FirmwareVersion': 'v2.73', 'Devices/00002CC001F4/Manufacturer':

358, 'Devices/00002CC001F4/ModelName': 'Cerbo GX', 'Devices/00002CC001F4/N2kUniqueNumber': 500, 'Devices/00002CC001F4/Nad': 149, 'Devices/00002CC001F4/Serial': '0000500', 'Devices/00002CC005EA/CustomName': 'Hub-1', 'Devices/00002CC005EA/DeviceInstance': 0, Page 149 Marine MFD integration by NMEA 2000 Requires the Actisense NGT-1. To change a Data instance: 1. Open Actisense NMEA Reader 2. Select data view (tab selection is at the bottom left) 3. Right click on the PGN number Note that this will only work on PGNs that allow changing their Data instance (first screenshot below) 4. And change the value (second screenshot below)