Nucleo GX Manual 16.3. Supported Devices As of Venus OS v2.90, RV-C output support has been added for a range of Victron products. The following devices are supported: Page 153 RV-C Support Victron product RV-C In RV-C Out Remarks VE.Bus Inverter/Charger Yes Inverter and charger functions can be controlled separately (on/off) via RV-C. Shore input current limit can also be set. Smart IP43 Charger 120-240V Yes Can be switched on/off via RV-C. Shore input current limit is configurable. Smart IP43 Charger 230V Yes Read-only via RV-C. Cannot be controlled. Skylla-i and Skylla-IP44/IP65 Yes Requires two fully functional CAN-bus interfaces.
Currently only supported by Venus GX, Cerbo GX MK2, Ekrano GX, and Nucleo GX. VE.Direct Inverter Yes Inverter Smart and Inverter RS Yes Solar chargers incl. MPPT RS Yes Orion XS Yes Only when charging from alternator Batteries: • BMV, SmartShunt, Lynx Shunt, Lynx Ion BMS, Lynx Smart BMS, Lynx BMS NG Yes Tanks: Tank level data is supported from the following input sources: • GX device tank level input • GX Tank 140 • VE.Can and/or NMEA 2000 port on the GX device Yes RV-C tank sensors • Note: The Garnet SeeLeveL II 709 sensor only reports relative tank level, as it does not provide absolute level or tank capacity.
Tanks connected via another GX device may show absolute level and capacity, but cannot be configured through RV-C. For advanced parameters and RV-C programming details, refer to the RV- C section in the appendix. Yes Generator auto start/stop Yes Only toggle the auto start option Third-part batteries • Battleborn • Lithionics Yes