Nucleo GX Manual 16.5. Garnet SeeLevel II 709-RVC & Victron GX device support With RV-C support in Venus OS, the Garnet SeeLevel 709-RVC and SeeLevel Soul can be used to display tank level data on both the GX device and VRM. All 709-RVC models and the SeeLevel Soul are compatible with the GX. Limitations When a CAN-bus port on a GX device is configured for RV-C, it cannot be used simultaneously for VE.Can or NMEA 2000 functions. It’s either VE.Can/NMEA 2000 or RV-C, not both on the same port. Devices such as the Venus GX, Cerbo GX MK2, Nucleo GX, and Ekrano GX, which have two fully functional VE.Can ports, support running VE.Can and RV-C in parallel.
If RV-C use blocks essential VE.Can connectivity on your GX device, it is recommended to use the Garnet SeeLevel 709- N2K instead, which communicates via NMEA 2000 and avoids these limitations. Tank levels shown on the GX device (and VRM) will appear as percentages only. The system does not display volume in litres, gallons, or other units. Before connecting to a GX device, ensure the Garnet SeeLevel 709-RVC is installed and configured according to Garnet’s installation instructions. 16.5.1. Wiring the Garnet SeeLevel II 709-RVC tank level sensor to a GX device The GX device requires an RJ45 connector on its VE.Can port, while the Garnet SeeLevel panel typically provides either:
A multi-pin RV-C connector, or A wired connection with one black, one blue, and one white wire. To connect the two, an adapter cable must be made based on the pin assignments provided below. A standard CAT5 Ethernet cable is well-suited for this purpose. One end of the cable is cut and connected to the Garnet panel wires, while the RJ45 plug remains on the GX device end. Victron VE.Can pinout 16.5.2. Installation and configuration 1. Route the cable from the Garnet panel to the GX device. 2. Ensure both the Garnet panel and GX device are powered off. 3. Connect the RJ45 plug to the VE.Can port of the GX device and the other end of the adapter cable to the Garnet panel. 4.
Check bus termination: For the GX device, use the supplied blue VE.Can RJ45 terminator. Proper termination is mandatory, especially if the Garnet SeeLevel is the only RV-C device on the bus. 5. Once everything is connected, power on both devices. 6. Complete the setup by following the steps in the RV-C Configuration chapter section to configure the VE.Can port for the RV-C profile. Page 156 RV-C Support Garnet panel wire colour code RV-C connector Victron VE.Can RJ45 CAT5 Ethernet wire colour code Signal Black 4 3 Green/White Ground Blue 3 8 Brown CAN-L White 2 7 Brown/White CAN-H