Nucleo GX Manual Grouping outputs Page 31 Connecting Victron products Once connected and powered, the GX IO-Extender 150 will appear in the Devices list on the GX device. The GX IO-Extender device's page displays: • Module state • Output state • PWM percentage • Output mode A dedicated Setup menu allows configuration of each output individually. On each individual output page in the Setup menu, the following options are available: • Custom name – Assign a unique name to the output. (Note: the module name can be changed via the Device menu). • Group: Allocate the output to a group. • Type: Select the output mode: Latching (Toggle), Momentary, or Dimmable. • Show controls:
Enable or disable visibility of the output in the Switch pane. Each output can be grouped by assigning a group name on the channel’s setup page. Outputs with the same group name are displayed together in a single group card on the Switch pane. This makes it easy to combine related outputs, for example, grouping all lighting outputs under one tile. Channels without a group name will appear in a card labelled with the module name.