Victron Nucleo GX — 6.11. Connecting IMT Solar Irradiance, Temperature and Wind Speed Sensors

Nucleo GX Manual Installation Notes The maximum DC power supply voltage permitted for the IMT Si-RS485 series solar irradiance sensor range is 28.0VDC. For 24V and 48V battery banks/systems, an appropriate Victron DC-DC converter (24/12, 24/24, 48/12 or 48/24), or AC-DC adapter must be used in the installation. For 12V battery banks or systems, the IMT Si-RS485 series solar irradiance sensors can be powered directly from the battery bank and will continue to operate down to a minimum voltage of 10.5V (as measured at the sensor, please account for voltage drop in the cable).

For detailed wiring, installation notes, and specifications, refer to the IMT Si-RS485 series solar irradiance sensor 'Quick Reference Guide' and the Victron RS485 to USB interface cable ‘Datasheet’ . To ensure signal integrity and robust operation, please adhere to the following guidelines: 1. Extension cabling must comply with the minimum cross-sectional area specifications listed in the related table, depending on DC supply voltage and cable length. 2. Extension cabling should have appropriate shielding and twisted pair cores. 3.

If the total cable length exceeds 10m or if there are installation-specific interference issues, the original cable attached to the Victron RS485 to USB interface should be reduced to a maximum length of 20cm. In such cases, use high-quality cabling for the entire length, rather than just the extension. 4. Ensure that cabling is installed separately from main DC or AC power cabling. 5. All wiring must be properly terminated (including unused wires) and adequately isolated from weather and water ingress. 6. Do not open or tamper with the sensor housing during installation, as this will compromise sealing integrity and void the warranty.

The IMT Si-RS485TC series solar irradiance sensor features internal galvanic isolation (up to 1000V) between the power supply and RS485 Modbus circuits, making the non-isolated Victron RS485 to USB interface suitable for most installations. However, if an isolated RS485 to USB interface is preferred, the only compatible device is Hjelmslund Electronics USB485- STIXL (other type will not be recognised by the GX device). Multiple Sensors It is not possible to connect multiple IMT Si-RS485 series solar irradiance sensors to a GX device; additional sensors will be ignored.

Generally, no special or additional configuration is required - the default 'as shipped' configuration is compatible for communication with a Victron GX device. Configuration However, if the IMT Si-RS485 series solar irradiance sensor has been previously used in another system or if the settings have been changed for any reason, it is necessary to restore the default configuration before further use. To revise the configuration, download the IMT 'Si-MODBUS-Configurator from the software downloads section . Follow the instructions in the Si-Modbus-Configurator manual, download from the same link and check or update the following settings:

Connecting supported non-Victron products Page 48 Si-Sensor Victron RS485 to USB interface Signal Brown Orange RS485 Data A + Orange Yellow RS485 Data B - Red - Power Pos - 12 to 28VDC Black - Power Neg/Gnd - 0VDC Black (thick) - Ground / Cable Shield / PE - Red Power Pos - 5VDC (not used) - Black Power Neg/Gnd - 0VDC (not used) - Brown Terminator 1 - 120R (not used) - Green Terminator 2 - 120R (not used) MODBUS Address: 1 Baud Rate: 9600 Data Format: 8N1 (10 Bit)