Nucleo GX Manual 6.17.1. How to connect the Sevcon controller to a GX device For an overview of Victron GX devices, see: https://www.victronenergy.com/live/venus-os:start CAN bus connection Connect the CAN output of the Sevcon controller to a VE.Can port on the Victron GX device. A modified RJ45 cable can be used. RJ45 pin assignment: Ensure all nodes on the CAN bus share a common ground. If a node is galvanically isolated from the Gen4 controller, its CAN ground must be connected to the Gen4 controller B-. CAN termination For systems with multiple CAN nodes: Use a daisy-chain topology Terminate both ends of the bus with a 120 Ω resistor If a Gen4 controller is used as an end node:
Link pins 2 and 24 on the customer connector (120 Ω termination is built in) For single-node systems: Ensure proper termination so the bus operates correctly, especially when using configuration tools On the VE.Can side, use a VE.Can terminator if required. Sevcon Gen4 Model support Tested with Sevcon Gen4 AC Size 4 controllers Expected to work with Size 2 and Size 6 controllers Gen4 DC controllers are not tested Connecting supported non-Victron products Page 67 Role RJ45 pin number Controller pin CAN Ground 3 (Green/White) B- CAN High 7 (Brown/White) 13 or 16 CAN Low 8 (Brown) 24 or 27