Victron Energy Nucleo GX — 9.2.4. Details on VE.Bus SOC

Nucleo GX Manual 9.2.3. Selecting SoC source 9.2.4. Details on VE.Bus SOC While the inverter/charger is in Bulk, the State of Charge (SoC) will not exceed the value set in VEConfigure under: General tab → State of charge when Bulk finished (default: 85%). In systems with solar chargers, ensure that the absorption voltage set in the MPPT is slightly higher than the setting in the inverter/charger. This allows the inverter/charger to detect the transition to Absorption, which is required for SoC to increase beyond the Bulk limit. If the inverter/charger does not detect Absorption, the SoC will remain fixed at the configured End-of-Bulk percentage (default: 85%).

Page 93 Configuration The State of Charge (SoC) source can be selected under: Settings → System Setup → Batteries → Battery monitor. The selected source determines which SoC value is displayed on the Overview screen of your GX device. Automatic mode When Automatic is selected, the system follows this logic: In the same image we have chosen the Automatic setting. When automatic is selected, the System setup screen will be as shown in the next image. The 'Automatic' function uses the following logic: 1. When available, it will use a dedicated battery monitor, such as the BMV, SmartShunt, Lynx Smart BMS or a Lynx Shunt VE.Can, or a battery with built-in battery monitor. 2.

When there is more than one of those connected, it will use a random one - although you can select one manually. 3. When there is no dedicated battery monitor, it will use the VE.Bus SoC. When to Use ‘No Battery Monitor’ Select No battery monitor in systems where: • A Multi or Quattro is installed • No BMV, SmartShunt, or equivalent monitor is present • Additional DC loads or chargers are connected to the battery but are not integrated with the GX device ⚠️ In this setup, the VE.Bus SoC may be inaccurate, as it does not account for unmonitored current from other DC sources or loads.