TwinCAT NC Axes All other axis parameters are to be set in the same way as for a servo axis. Here in particular empirical tests for the setting of the acceleration, deceleration and max jerk are to be carried out with the maximum expected mass to be moved in operation. Here it may not happen that the axis leaves out part of the movement due to overload. Notice Stepper motors have a more or less distinctive natural resonance. This can lead to problems in the case of very flat ramps or unfavorably selected target velocities.
The axis will then generate significant noise and can then be shifted and lose its correct reference by one or more polling cycles due to superposition of the travel movement with a low frequency jitter movement caused by brief overloading. 4.4 "Low Cost" stepper motor axes with digital control (24V / 2A) The basic version of the 'low cost stepper motor axis' is operated without physical encoder (hence simulation encoder). This means that there is no actual physical feedback between set values and actual values, and therefore the axis is not operated with closed-loop control, but only with open-loop control.
It is assumed that there is no slippage in the drive, and that the axis can accurately follow the specified step pattern (set value profile). Notwithstanding this constraint imposed for cost reasons, the stepper motor axis can be referenced physically, since the simulation encoder is implemented as an incremental encoder and supports virtually all features. Configuration of the "low cost" stepper motor axis Axis type: 'low cost stepper motor axis' (dig. I/O)' Encoder type: 'simulation encoder' Controller type: 'stepper motor controller' Drive type:
'stepper motor drive' Referencing As usual, the digital referencing cam signal has to be mirrored into the axis interface to the NC (PlcToNc axis structure) via the PLC. The usual procedure for referencing an axis applies, but the hardware feature "latching of a position", initiated by a sync impulse, is not available. Instead, the falling edge is used as local event for determining a reference position during ramp-down from the referencing cam. The accuracy of the referencing process can be increased as required through a reduction in velocity during ramp-down from the cam (the maximum possible precision is one motor step).
Commissioning instructions At this point, it is worth mentioning some technical restrictions of stepper motors. Note that all recommended tests have to be carried out under load. The maximum permitted limit frequency max v f [kHz] of the stepper motor in motion must not be exceeded, since otherwise the linear range of the drive would be exceeded and the drive limit approached. The maximum start and stop frequency / max start stop f [kHz] during starting and stopping of the axis must not be exceeded, since otherwise the stepper motor could "lose steps" during this positioning start and end phase.
a d [kHz/s] must not be exceeded during the start and stop phase of the motion, since otherwise steps could be "lost" here too. max The maximum acceleration and deceleration max Numerical Control (NC) Basics 26 Version: 1.2