TwinCAT NC Axes Stepper motor parameters Table 1: Motor parameters Numerical Control (NC) Basics 28 Version: 1.2 Parameters Description Stepper motor operating mode The stepper motor can be operated in different operating modes through the type of control used. The period at which various step pattern combinations are output can thus be set. The step size (full step or half step) and the motor torque can thus be influenced. The available operating modes are described in the "stepper motor operating mode" table below. Displacement per step dS Step Physical scaling of a motor step (step change) according to the mechanical conditions such as gearbox, etc. Unit:
[mm/INC] Minimum velocity for velocity profile V min For generating the velocity profile, this minimum velocity Vmin is used as the start and end velocity of the calculated velocity profile, provided the required set velocity can be reached on the travel path. Obviously, due to the time discretisation (cycle time) not every velocity level can be reached. Only a certain number of discrete velocity levels is available (proportional to 1/(n*dT) with n=1,2,3... and dT axis cycle time in seconds). The value is rounded, and the next possible velocity level is used. Unit:
[mm/s] Number of steps per velocity level >N level According to the boundary conditions (minimum velocity, target velocity, travel path), a velocity profile with discrete velocity levels (proportional to the step frequency) is calculated. Maintaining of a certain velocity level in the range between 0 to 100 relative to the motor steps can be set via this parameter. The parameter Nlevel can therefore be used for scaling (extending or reducing) the velocity ramp. For the limit case of Nlevel = 0, no ramped velocity profile is generated, but the required set velocity is kept constant for the entire travel path. Unit: 1