TwinCAT NC Axis components Encoder types 1. Simulation encoders 2. Absolute, with 24 or 25 bits, and 12 and 13 bit single turn encoders (M3000) 3. Incremental, with 24 bits (M31x0, M3100, M2000) 4. Incremental, with 16 bits (KL5101) 5. Absolute SSI with 24 bits (KL5001) 6. Absolute/incremental BISSI with 16 bits (KL5051 and PWM Terminal KL2502_30K (frq. cnt. pulse mode) ) 7. Absolute analog input with 16 bits (KL30xx) 8. SERCOS "Encoder" POS 9. SERCOS "Encoder" POS and VELO 10. Binary incremental encoders (0/1) 11. Absolute analog input with 12 bits (KL2510) 12. T&R Fox 50 module (24 bits absolute (SSI)) 13. Force acquisition from Pa, Pb, Aa, Ab 14. Incremental with 16/20 bits (AX2000) 15.
Incremental with 32 Bit 16. Incremental with variable bit mask (max. 32 bits) 17. Incremental NC backplane Encoder parameters Numerical Control (NC) Basics 32 Version: 1.2 Parameter Data type Unit Description ENCODER mode ENUM Operation mode of the encoder: POS = the actual position is determined. POSVELO = the actual position and the actual velocity are determined. POSVELOACC = the actual position, actual velocity and the actual acceleration are determined. Encoder counting direction inverted BOOL Counting direction inverted: FALSE = the polarity of the axis movement agrees with the counting direction of the acquisition hardware.
TRUE = the polarity of the axis movement is in the opposite sense to that of the counting direction of the acquisition hardware. Scaling factor float mm/INC Incremental evaluation: this factor is used to convert the displacement increments into axis positions. Zero offset shift float mm With absolute encoders: this value is added to the encoder position in order to determine the axis position. It is used to specify the machine-dependent zero point. Modulo factor float mm With rotary axes: this is the "distance" represented by one rotation. If the actual value is acquired, for instance, in degrees, 360.0 should be entered here. OPERATING MODE: min.
end position monitoring BOOL Activation and deactivation of the monitoring of the minimum end position. Software end position, min. float mm Location of the minimum end position OPERATING MODE: max. end position monitoring BOOL Activation and deactivation of the monitoring of the maximum end position. Software end position, max. float mm Location of the maximum end position Actual position filter time float>0 s Filter time for the PT1 filtering of the actual position. Actual velocity filter time float>0 s Filter time for the PT1 filtering of the actual velocity.