beckhoff TwinCAT 2 — 5.7.4 Discrete high/low speed axis (two speed)

TwinCAT NC Axis components Requirements 5.7.4 Discrete high/low speed axis (two speed) An override modification (also override = 0) only takes effect within the main travel phase [ } 14] . If the override is set to 0 within one of the braking phases [ } 14] , the initiated braking phase is ended without being influenced. Numerical Control (NC) Basics 54 Version: 1.2 No. Data type Byte Bit Def.- Range Variable name Variable name (from 2.11 or TcMc2) Description 4 UINT32 12-15 - nAxisMode DWord AxisModeDWord Only provided for internal use! 5 REAL64 16-23 - fAxisMode LReal AxisModeLReal Only provided for internal use!

6 REAL64 24-31 - fActPosCo rrection PositionCorrection Actual position correction value 7 REAL64 32-39 - fExtSetPos ExtSetPos External set position 8 REAL64 40-47 - fExtSetVel o ExtSetVelo External set velocity 9 REAL64 48-55 - fExtSetAcc ExtSetAcc External set acceleration 10 INT32 56-59 - nExtSetDir ection ExtSetDirection External set travel direction [-1,0,1] 11 UINT32 60-63 - nReserved 1 - RESERVE 12 REAL64 64-71 - fExtCtrlOut put ExtControllerOutpu t External controller output. Not yet released!

13 REAL64 72-79 - ±∞ - GearRatio1 Gear ratio (coupling factor) 1 14 REAL64 80-87 - ±∞ - GearRatio2 Gear ratio (coupling factor) 2 15 REAL64 88-95 - ±∞ - GearRatio3 Gear ratio (coupling factor) 3 16 REAL64 96-10 3 - ±∞ - GearRatio4 Gear ratio (coupling factor) 4 17 - 104-1 27 - - nReserved - RESERVE Development environment Target platform PLC libraries to include TwinCAT v2.7.0 PC (i386) PlcNc.Lib TwinCAT v2.8.0 PC (i386) TcNC.Lib Starting velocity value range V Interpretation of the starting velocity with 100% override (required travel velocity / travel stage) V > 50 Rapid traverse 0 Slow traverse V ≤ 0 ERROR Value range override X Interpretation of the override value ( 100% = 1,000,000 ) X > 50% (500000) Rapid traverse 0% Slow traverse X = 0% Stationary (tolerance window: