Axis commissioning 6 Axis commissioning General The requirements for commissioning axes [ } 57] include, in particular, knowledge and use of the NC's safety functions along with a grasp of the necessary precautions along with the observation of a specific sequence of commissioning steps for the axis elements (encoder, drive and controller), as well as setting the axis parameters. Encoders and actual values Determination and setting the most important encoder parameters [ } 59] : encoder polarity, scaling (increments per mm), position offset (zero offset shift). Drive and voltage output Determination [ } 61] and setting the most important drive parameters:
drive polarity, reference output, reference speed, drift compensation. Position control and reduction of the following error Determination and setting the most important position control parameters [ } 62] : Kv factor and parameters for reduction of the following error. Axis parameters, axis monitoring and axis calibration Determination and setting the most important axis parameters [ } 64] : maximum velocity, following error monitoring, end position monitoring and the parameters for dynamic behaviour and calibration.
6.1 General Axis commissioning particularly requires knowledge and use of the safety functions of the NC, application of the necessary safety precautions, and the observance of a particular sequence of commissioning steps. DANGER Risk of injury due to movement of axes! The commissioning results in a movement of axes. Make sure that neither you nor others are harmed by the movement, e.g. by maintaining a suitable safety distance. Do not perform any action whose consequences you cannot estimate WARNING Incorrect axis position during initial commissioning Without referencing / calibrating the axis position, the displayed axis position may deviate from the actual axis position.
Perform a homing to determine the correct actual position using a reference signal. General safety precautions Make sure that you know about the NC safety functions [ } 10] , and make use of them. Handling the emergency stop case is one of the most important and safety-relevant features of a machine. For this reason it is usual for an additional hardware safety circuit to be built on top of all the logical (logical axis enables) and software enables (PLC: controller and feed enables). Extensive statutory regulations exist governing the reaction and the implementation in hardware of the emergency stop system. Here we shall only make reference to these.
Numerical Control (NC) Basics 57 Version: 1.2