omron — 3-4-1 Wiring the Robot Integrated CPU Unit and the EtherCAT Digital I/O Terminal

3 Implementation Example of Static Pick-and-place Equipment 3-4 Installing and Wiring the System In the system configuration, you must wire the signal lines covered in the colored areas in the figure below and set the node address of the robot.

• Wiring between the Robot Integrated CPU Unit (A) and the EtherCAT Digital I/O Terminal (F) • Wiring between the EtherCAT Digital I/O Terminal (F) and the robot (C) • Wiring between the Robot Integrated CPU Unit (A) and the computer (E) • Wiring between the robot (C) and the T20 pendant (I) • Wiring between the robot (C) and the front panel (K) • Wiring between the EtherCAT Digital I/O Terminal (F) and the solenoid valve (Q) (B) (A) (E) (G) 100 to 240 VAC (D) (C) (F) (R) (H) (S) (Q) (I) (P) XMCP (J) 85 to 264VAC, 6.5A (M) (O) (K) XFP XUSR *1 (L) Single phase, AC200 to 240VAC, 10A (N) Refer to 1-3 System Configuration for Static Pick-and-place Equipment on page 1-4 for information on the parts used in the system configuration.

Refer to the manual for the specific product for details on power lines not covered in the colored area as well as for ducting from the robot. 3-4-1 Wiring the Robot Integrated CPU Unit and the EtherCAT Digital I/O Terminal You must wire the Robot Integrated CPU Unit and the EtherCAT Digital I/O Terminal. 1 Connect the EtherCAT port of the Robot Integrated CPU Unit and the EtherCAT IN port of the EtherCAT Digital I/O Terminal with an Ethernet cable. 3-86 NJ-series Robot Integrated System Startup Guide (O049)