4 Implementation Example of Dynamic Pick-and-place Equipment In this equipment, Pack Manager sample is used to program the pick-and-place operation. If you use the Pack Manager sample, you can operate the robot by using the Process Manager func- tion of the IPC Application Controller. It eliminates the need to create complex programs for process- ing to work with peripheral devices. However, you need to make the V+ programs and C# programs to start or stop the Process Manager. Process Manager can be started or stopped by calling the C# program, which is executed by the IPC Application Controller, from the V+ program that is running on the Robot Integrated CPU Unit.
Process Manager's solenoid valve opening/closing instruction is written to outputs of V+ Digital I/O. They are assigned to the contacts of the EtherCAT I/O Slave by the V+ Digital I/O Settings function and are output from those contacts. Process Manager's conveyor drive ON/OFF instruction is written to the output of V+ Digital I/O. The V + program for regular processing, "control", polls for the status of the conveyor drive ON/OFF instruc- tion and writes it to the shared variable.
In addition, the sequence control program "ConveyerControl" polls for the shared variables, converts them to operational instructions (ON/OFF instructions, velocity command, and rotational directions), and outputs them to the inverter. This section describes the sequence control program to control the dynamic pick-and-place equip- ment. In the sequence control program, register global variables and create three programs, "Main" (main program), "ConveyerControl", and "RobotControl". Global Variables Register the global variables that are used in the sequence control program. The following variables are automatically generated in the I/O Map tab page. Register the variables below yourself.
4-4 NJ-series Robot Integrated System Startup Guide (O049) Sequence Control Program Name Data type Comment E002 Command _ WORD Inverter run command E002 Frequency reference _ _ UINT Inverter target frequency E002 Status _ WORD Inverter status E002 Output frequency monitor _ _ _ UINT Inverter frequency monitor E002 Sysmac Error Status _ _ _ BYTE Inverter Sysmac error Name Data type Comment e conveyor dir _ _ BOOL Conveyor revere command e conveyor run _ _ BOOL Conveyor run command e conveyor spd _ _ BOOL Conveyor fast run command e is run mode _ _ _ BOOL Operation mode gRC Err _ BOOL Robot control error gReset BOOL Auto-operation stopped gStart BOOL Auto-operation started gSysOK BOOL Operation ready eBool exeT1 _ BOOL supervisor in execution gEnableT1 BOOL supervisor executable