omron — 4-1-1 Program Structure

4 Implementation Example of Dynamic Pick-and-place Equipment 4-1 Program Specifications for Dynamic Pick-and-place Equipment In this section, you create five V+ programs: "px.start" to call the C# program for starting the Process Manager, "px.stop" to call the C# program for stopping the Process Manager, the status monitoring program "supervisor", the regular processing program "control", and the startup processing program "auto".  V+Digital I/O Communications between multiple V+ programs or between V+ programs and external EtherCAT Digital I/O Terminals are performed via V+ Digital I/Os. The I/O number to be used is shown below. Set No.4001 from the V+Digital I/O Settings.

4  Program to Call C# Program for Starting (px.start) 4-1-1 Program Structure This section describes the program to call the C# programs for starting the Process Manager. An example of a program is provided below. Additional Information You cannot use the program with Sysmac Studio version 1.42. Use the program with Sysmac Studio version 1.43 or higher. On Sysmac Studio ver.1.42, go online with the IPC Application Controller, select ApplicationManager1 - C# Program - PM_Start and click the Start button on the Task Status Control pane.

.PROGRAM px.start() GLOBAL $ip AUTO REAL status TYPE "Start PM_Start" 4-7 NJ-series Robot Integrated System Startup Guide (O049) Range Number Applications Outputs Not used Inputs 1001 Soft Signals 2001 2002 2003 Robot Signals Not used External 4001