4 Implementation Example of Dynamic Pick-and-place Equipment 4-3 Programming and Simulation Procedures 4 4-3-6 Creating a Pack Manager Sample You can set the points by a drag and drop operation on the 3D Visualizer or by directly entering data in numeric entry fields of Belt Control . Set the points in either way. • Dragging and Dropping on the 3D Visualizer Refer to A-2 How to Use 3D Visualizer on page A-21 and the Sysmac Studio Robot Integrated System Building Function with IPC Application Controller Operation Manual (Cat. No. W621) for operation procedure of the 3D Visualizer. The conveyor can be moved by dragging and dropping the green, red, and blue arrows.
The Upstream Limit is the position indicated by the purple point and the green arrow (origin of Belt Transformation and Y-axis). The Pick Limit is indicated by a purple line and the Downstream Limit by a blue line. The Pick Limit and Downstream Limit can be moved by dragging and dropping the yellow ar- row. 4-69 NJ-series Robot Integrated System Startup Guide (O049) Letter Item Description A Upstream Limit The limit position upstream of the conveyor to make a pick operation. The robot does not pick at the conveyor position upstream from the Upstream Limit. B Pick Limit The reference limit position downstream of the conveyor to make a pick opera- tion.
When the placement is completed, the robot specifies the next workpiece to pick and calculates the pick position. At that time, workpieces that exist downstream from the Pick Limit are excluded from the pick target. C Down- stream Lim- it The limit position downstream of the conveyor to make pick operation. The robot does not pick at the conveyor position downstream from the Downstream Limit.