4 Implementation Example of Dynamic Pick-and-place Equipment 4-4 Installing and Wiring the System 2 Wire the power I/O cable and the XIO breakout cable. Make a connector or relay with a termi- nal block as shown in the following wiring diagram. XIO breakout cable Yellow Red/black Gray 4 Power I/O cable 4-4-12 Wiring the EtherCAT Digital I/O Terminal and Solenoid Valve Red White/black White 3 Connect the XIO breakout cable and the robot. Precautions for Correct Use Refer to Configuring the Camera, Conveyor, and Encoder on page 4-65 for the installation loca- tion of the camera. You must install the camera between the upstream limit set by the software and the entrance of the conveyor.
4-4-12 Wiring the EtherCAT Digital I/O Terminal and Solenoid Valve You must wire the EtherCAT Digital I/O Terminal and the solenoid valve. Refer to the manuals for the EtherCAT Digital I/O Terminal and the solenoid valve for details on the cable wiring, and make the cable appropriately in accordance with the wiring diagrams and specifica- tions. 1 Make the cable so that the solenoid valve will behave as shown in the table below. 4-101 NJ-series Robot Integrated System Startup Guide (O049)