4 Implementation Example of Dynamic Pick-and-place Equipment 17 Change the operating mode to Auto mode from Manual mode on the front panel, and click the Power button. When the Robot Power button on the front panel flashes, press it to turn on the robot high power. 18 Move the robot to the upstream of the belt, then click the Start Tracking button in Belt Transform in the Test Belt Calibration window. 4-5 Operation Check on the Actual System The robot moves as the belt moves. 19 Click the Stop Tracking button if you have confirmed the robot moved as the belt moved. 4 4-5-8 Calibrating the Sensor The tracking operation stops. 20 Click the Finish button.
The Robot-to-Belt Calibration Sequence dialog is closed. 4-5-8 Calibrating the Sensor Calibrate the sensor. Additional Information • The procedure in this section includes steps for detecting the target. It is for position detection required for calibration of the sensor. For settings of the locater model to detect an actual tar- get, refer to 4-5-9 Setting the Locator on page 4-146. • If the target cannot be detected, adjust the camera's shooting environment or the acquisition settings. Refer to the Automation Control Environment (ACE) Version 4 User's Manual (Cat. No. I633) for information on the acquisition settings of the virtual camera.
1 Select ApplicationManager1 from the device list in Multiview Explorer. 4-135 NJ-series Robot Integrated System Startup Guide (O049)