4 Implementation Example of Dynamic Pick-and-place Equipment 4-5 Operation Check on the Actual System The Synchronization window is closed. 17 Disconnect Sysmac Studio (offline) to the Robot Integrated CPU Unit and IPC Application Con- troller. To go offline, select Offline instead of Online in the processes described in Connecting Sys- mac Studio to the Robot Integrated CPU Unit Online on page 4-110 and Going Online with the IPC Application Controller on page 4-111. 4 4-5-11 Running the Program to Check the Operation 18 Power off the Robot Integrated CPU Unit and IPC Application Controller. 19 Power on the Robot Integrated CPU Unit and IPC Application Controller.
20 Boot up ACE as a server in the IPC Application Controller. Refer to Automation Control Environment (ACE) Version 4 User’s Manual (Cat. No.I633) for the ACE server instance. 21 Establish an online connection between Sysmac Studio and the Robot Integrated CPU Unit. Refer to Connecting Sysmac Studio to the Robot Integrated CPU Unit Online on page 4-110 for the procedure to connect online. 22 Set TRUE to gStart in the Watch (Project)1 tab page. Refer to 4-5-5 Running a Sequence Control Program and V+ Program on page 4-126 for how to open the Watch tab page. 23 Turn on the robot high power on the robot front panel. 1) Switch the front panel to Auto mode.
4-161 NJ-series Robot Integrated System Startup Guide (O049)