Appendices A-1 Designing Example of the Safety Functions for the Pick-and-place Equip- ment Auto Mode Set the safety functions when the operating mode of the OMRON robot is in Auto mode as shown in the table below. Set the safety functions when the operating mode of the OMRON robot is in Manual mode as shown in the table below. A A-1-5 Safety System Configuration and Devices A-1-5 Safety System Configuration and Devices You must select the safety system configuration and devices for it to achieve the safety functions. The safety system configuration in this guide uses an NX-series EtherNet/IP Coupler Unit and NX-ser- ies Safety Control Units.
A-5 NJ-series Robot Integrated System Startup Guide (O049) Safety device Safety function Recovery Emergency stop pushbutton switch 1 Stop the robot when pressed High power ON after resetting Emergency stop pushbutton switch 2 Stop the robot when pressed High power ON after resetting Safety light curtain 1 Stop the robot when the beam is inter- rupted High power ON Safety light curtain 2 Stop the robot when beam is interrupted High power ON Safety door switch 1 Stop the robot when the door is open High power ON after resetting Safety door switch 2 Stop the robot when the door is open High power ON after resetting E-STOP button on front panel Stop the robot when pressed High power ON after resetting E-STOP button on T20 pendant Stop the robot when pressed High power ON after resetting Enable switch on T20 pendant --- --- Manual Mode Safety device Safety function Recovery Emergency stop pushbutton switch 1 Stop the robot when pressed Reset Emergency stop pushbutton switch 2 Stop the robot when pressed Reset Safety light curtain 1 --- --- Safety light curtain 2 --- --- Safety door switch 1 --- --- Safety door switch 2 --- --- E-STOP button on front panel Stop the robot when pressed Reset E-STOP button on T20 pendant Stop the robot when pressed Reset Enable switch on T20 pendant Stop the robot when not pressed or fully pressed pass- ing the middle position High power ON Safety System Configuration